MINIMUM DISTANCE BETWEEN DEVICES IS 50 METERS.
In particular, devices MUST NOT be tested by directing one antenna against the other in close proximity - it can lead to PERMANENT RADIO DAMAGE.
Miure Duo has been designed for outdoor operation - all performance tests conducted indoors WILL NOT give any authoritative results due to different radio wave propagation.
Device requires clear line of sight.
The 5GHz band is highly attenuated by objects like buildings, trees, etc. For undisturbed transmission special care should be taken about ensuring clearness of the so-called Fresnel zone - the longer the link distance, the greater should be the free area around transmitted radio waves. "Aiming" through "bottlenecks" should be avoided.
Antennas must be aligned during device installation - otherwise devices may not operate at their full potential and/or the link may be unstable.
Device does not operate without connected Ethernet signal.
The "Ethernet" port of the power supply should be connected to a network device, like hub, switch, router, laptop, etc.
Device needs 60 seconds for radio transmission stabilization.
After establishing the radio connection, Miure Duo will start to probe the transmission medium and will become fully operable after max. 60 seconds.
Antenna operating frequency range is 5.4-5.9GHz.
On other frequencies the device may operate suboptimally (see p. 1.2.). Additionally, minimal separation between the main and secondary frequencies should be greater than twice the selected channel width.